ASAP Semiconductor is an industry-leading distributor for shopping for parts by National Stock Number (NSN) data, the items featured within this catalog all falling under NSN 5915-01-337-9178 (5915013379178). Toward the top of this page, you will find several details that pertain to this NSN, allowing you to confirm various aspects of these offerings to ensure accurate procurement. Meanwhile, the part numbers that we have available for purchase can be found below, with Request for Quote (RFQ) links provided alongside each should you wish to make a purchase. Our team is also available by phone or email to support you during the procurement process, so never hesitate to take the first step with us.
Alternative NSN: | 5915013379178 |
Manufacturers | Amphenol Corporation , Dla Land And Maritime , Hamilton Sundstrand Corporation , Itt Corporation , Tyco Electronics Corporation |
Item Name | Filter Radio Frequency Interfere |
INC Code | 00765 |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5915 Filters and Networks |
National Item Identification Number (NIIN) | 01-337-9178 (013379178) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | CAGE Code | Type | Status | Availability | RFQ | |
---|---|---|---|---|---|---|---|---|
21-529011-207 | amphenol corporation | filter radio frequency interfere | 77820 | a | a | Avl | RFQ |
|
797028-1 | amphenol corporation | filter radio frequency interfere | 77820 | a | a | Avl | RFQ |
|
797028-1 | itt corporation | filter radio frequency interfere | 71468 | a | a | Avl | RFQ |
|
797028-1 | hamilton sundstrand corporation | filter radio frequency interfere | 73030 | a | a | Avl | RFQ |
|
86-4055-020-1 | tyco electronics corporation | filter radio frequency interfere | 00779 | a | a | Avl | RFQ |
|
NH797028-1 | dla land and maritime | filter radio frequency interfere | 16236 | a | a | Avl | RFQ |
|
TKJL110703-85 | itt corporation | filter radio frequency interfere | 71468 | a | a | Avl | RFQ |
|
MRC | Criteria | Characteristic |
---|---|---|
AFSV | AVERAGE LIFE RATING IN HOURS | 500.0 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 2ND RADIO INTERFERENCE AND 2.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 73030 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 2.5 AND 17.0 AND 40.0 |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE AND 200.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 4TH RADIO INTERFERENCE AND 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
ABHP | OVERALL LENGTH | 1.685 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.020 INCHES MINIMUM AND 1.040 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.020 INCHES MINIMUM AND 1.040 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.122 INCHES MINIMUM AND 0.136 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.772 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 1ST RADIO INTERFERENCE AND 2.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 3RD RADIO INTERFERENCE AND 2.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 4TH RADIO INTERFERENCE AND 2.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 5TH RADIO INTERFERENCE AND 2.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBP | INPUT TERMINAL IDENTIFICATION | SMA CONNECTOR PLUG |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 73030 |
AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
CBBL | FEATURES PROVIDED | MOISTURE RESISTANT AND SHOCK RESISTANT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 200.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 6TH RADIO INTERFERENCE AND 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | ALUMINUM |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | CADMIUM |
FEAT | SPECIAL FEATURES | NUCLEAR HARDNESS CRITICAL ITEM |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
PRMT | PRECIOUS MATERIAL | GOLD |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 6TH RADIO INTERFERENCE AND 2.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 200.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 5TH RADIO INTERFERENCE AND 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.772 INCHES NOMINAL |
5945-01-417-4215 (5945014174215) | 5935-01-075-6787 (5935010756787) | 5905-00-944-9222 (5905009449222) | 5998-01-244-8813 (5998012448813) |
5915-00-907-5624 (5915009075624) | 5950-00-965-9761 (5950009659761) | 5905-00-799-8794 (5905007998794) | 5910-00-405-8227 (5910004058227) |
5998-01-109-7002 (5998011097002) | 5940-01-284-2691 (5940012842691) | 5920-01-502-5817 (5920015025817) | 5905-00-969-6448 (5905009696448) |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.