ASAP Semiconductor is an industry-leading distributor for shopping for parts by National Stock Number (NSN) data, the items featured within this catalog all falling under NSN 5925-00-115-8114 (5925001158114). Toward the top of this page, you will find several details that pertain to this NSN, allowing you to confirm various aspects of these offerings to ensure accurate procurement. Meanwhile, the part numbers that we have available for purchase can be found below, with Request for Quote (RFQ) links provided alongside each should you wish to make a purchase. Our team is also available by phone or email to support you during the procurement process, so never hesitate to take the first step with us.
Alternative NSN: | 5925001158114 |
Manufacturers | Westinghouse Electric Corp |
Item Name | Circuit Breaker |
INC Code | 00136 |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-115-8114 (001158114) |
NCB Code | USA (00) |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 3.015 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.375 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.000 INCHES NOMINAL |
AJEC | BOSS HEIGHT | 0.187 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 14.000 MINIMUM AT 200 PCT AND 115.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CLIP AND 2 SCREW |
5945-01-417-4215 (5945014174215) | 5935-01-075-6787 (5935010756787) | 5905-00-944-9222 (5905009449222) | 5998-01-244-8813 (5998012448813) |
5915-00-907-5624 (5915009075624) | 5950-00-965-9761 (5950009659761) | 5905-00-799-8794 (5905007998794) | 5910-00-405-8227 (5910004058227) |
5998-01-109-7002 (5998011097002) | 5940-01-284-2691 (5940012842691) | 5920-01-502-5817 (5920015025817) | 5905-00-969-6448 (5905009696448) |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote