ASAP Semiconductor is an industry-leading distributor for shopping for parts by National Stock Number (NSN) data, the items featured within this catalog all falling under NSN 5925-00-933-6041 (5925009336041). Toward the top of this page, you will find several details that pertain to this NSN, allowing you to confirm various aspects of these offerings to ensure accurate procurement. Meanwhile, the part numbers that we have available for purchase can be found below, with Request for Quote (RFQ) links provided alongside each should you wish to make a purchase. Our team is also available by phone or email to support you during the procurement process, so never hesitate to take the first step with us.
Alternative NSN: | 5925009336041 |
Manufacturers | Eastman Kodak Company , Eaton Corporation , Wood Electric Operations Potter And Brumfield |
Item Name | Circuit Breaker |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-933-6041 (009336041) |
NCB Code | USA (00) |
Part No | Manufacturer | Item Name | CAGE Code | Type | Status | Availability | RFQ | |
---|---|---|---|---|---|---|---|---|
037-225 | eastman kodak company | circuit breaker | 32153 | a | c | Avl | RFQ |
|
190-230-101 | wood electric operations potter and brumfield | circuit breaker | 79405 | a | h | Avl | RFQ |
|
AM33-30-250VAC60C4 | eaton corporation | circuit breaker | 74193 | a | h | Avl | RFQ |
|
AM33MG6-30-250-4-60 | eaton corporation | circuit breaker | 74193 | a | h | Avl | RFQ |
|
AM33MG6-30-250-60CYC4 | eaton corporation | circuit breaker | 74193 | a | h | Avl | RFQ |
|
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | EXPLOSION RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
APNQ | Arc Quenching Method | AIR |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 11.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
5945-01-417-4215 (5945014174215) | 5935-01-075-6787 (5935010756787) | 5905-00-944-9222 (5905009449222) | 5998-01-244-8813 (5998012448813) |
5915-00-907-5624 (5915009075624) | 5950-00-965-9761 (5950009659761) | 5905-00-799-8794 (5905007998794) | 5910-00-405-8227 (5910004058227) |
5998-01-109-7002 (5998011097002) | 5940-01-284-2691 (5940012842691) | 5920-01-502-5817 (5920015025817) | 5905-00-969-6448 (5905009696448) |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.