ASAP Semiconductor is an industry-leading distributor for shopping for parts by National Stock Number (NSN) data, the items featured within this catalog all falling under NSN 5945-00-785-3264 (5945007853264). Toward the top of this page, you will find several details that pertain to this NSN, allowing you to confirm various aspects of these offerings to ensure accurate procurement. Meanwhile, the part numbers that we have available for purchase can be found below, with Request for Quote (RFQ) links provided alongside each should you wish to make a purchase. Our team is also available by phone or email to support you during the procurement process, so never hesitate to take the first step with us.
Alternative NSN: | 5945007853264 |
Manufacturers | D And J Parts Inc , L And L Boiler Maintenance Inc , Tyco Electronics Agastat Relays |
Item Name | Relay Electromagnetic |
INC Code | 32512 |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-785-3264 (007853264) |
NCB Code | USA (00) |
Part No | Manufacturer | Item Name | CAGE Code | Type | Status | Availability | RFQ | |
---|---|---|---|---|---|---|---|---|
159107071 | d and j parts inc | relay electromagnetic | 54108 | a | r | Avl | RFQ |
|
159107071 | l and l boiler maintenance inc | relay electromagnetic | 0atf2 | f | a | Avl | RFQ |
|
2422L9CN | tyco electronics agastat relays | relay electromagnetic | 89020 | a | a | Avl | RFQ |
|
2496A1 | tyco electronics agastat relays | relay electromagnetic | 89020 | a | a | Avl | RFQ |
|
7022L9CN | tyco electronics agastat relays | relay electromagnetic | 89020 | a | a | Avl | RFQ |
|
999301048SH1PC6 | l and l boiler maintenance inc | relay electromagnetic | 0atf2 | f | a | Avl | RFQ |
|
999301048SH1PC6 | d and j parts inc | relay electromagnetic | 54108 | a | r | Avl | RFQ |
|
MRC | Criteria | Characteristic |
---|---|---|
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 230.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.090 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
CBME | CUBIC MEASURE | 45.392 CUBIC INCHES |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 1.50 SECONDS MINIMUM ADJUSTABLE RELEASE TIME AND 15.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
5945-01-417-4215 (5945014174215) | 5935-01-075-6787 (5935010756787) | 5905-00-944-9222 (5905009449222) | 5998-01-244-8813 (5998012448813) |
5915-00-907-5624 (5915009075624) | 5950-00-965-9761 (5950009659761) | 5905-00-799-8794 (5905007998794) | 5910-00-405-8227 (5910004058227) |
5998-01-109-7002 (5998011097002) | 5940-01-284-2691 (5940012842691) | 5920-01-502-5817 (5920015025817) | 5905-00-969-6448 (5905009696448) |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote