ASAP Semiconductor is an industry-leading distributor for shopping for parts by National Stock Number (NSN) data, the items featured within this catalog all falling under NSN 6630-01-242-4050 (6630012424050). Toward the top of this page, you will find several details that pertain to this NSN, allowing you to confirm various aspects of these offerings to ensure accurate procurement. Meanwhile, the part numbers that we have available for purchase can be found below, with Request for Quote (RFQ) links provided alongside each should you wish to make a purchase. Our team is also available by phone or email to support you during the procurement process, so never hesitate to take the first step with us.
Alternative NSN: | 6630012424050 |
Manufacturers | Thermo Orion Inc |
Item Name | Analyzer Sodium Potassium |
INC Code | 38487 |
Federal Supply Group (FSG) | 66 Instruments and Laboratory Equipment |
Federal Supply Class (FSC) | 6630 Chemical Analysis Instruments |
National Item Identification Number (NIIN) | 01-242-4050 (012424050) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | CAGE Code | Type | Status | Availability | RFQ | |
---|---|---|---|---|---|---|---|---|
210201 | thermo orion inc | analyzer sodium potassium | 30260 | a | a | Avl | RFQ |
|
MODEL-1020 | thermo orion inc | analyzer sodium potassium | 30260 | a | a | Avl | RFQ |
|
MRC | Criteria | Characteristic |
---|---|---|
CYFZ | TEST SAMPLE/SPECIMEN SIZE | 100 MICROLITERS OF BLOOD OR 400 MICROLITERS OF PREDILUTED URINE |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | POTASSIUM ELECTRODE,1; SODIUM ELECTRODE,1; REFERENCE ELECTRODE,1; BOTTLE OF STANDARD A,2; BOTTLE OF STANDARD B,1; WASTE BOTTLE,1; BOTTLE OF REFERENCE FILLING SOLUTION,1; BOTTLE OF TEST DYE SOLUTION,1; REFERENCE MEMBRANE ASSEMBLY,2; FLUID PATH MODULE,1; BOTTLE ELECTRODE RINSE SOLUTION,1; SLIDE VALVE,1; SAMPLE PROBE ASSEMLBY,1 |
CYFX | ELECTRODE TYPE | POTASSIUM/K+ AND REFERENCE AND SODIUM/NA+ |
CYFV | METHOD OF ANALYSIS | POTENTIOMETRIC/ION SELECTIVE ELECTRODE |
ABRN | HEIGHT | 360.0 MILLIMETERS |
DPTH | DEPTH | 230.0 MILLIMETERS |
ELEC | VOLTAGE IN VOLTS | 120.0 OR 230.0 |
CYFY | ANALYSIS TEST/MEASUREMENT RANGE | SODIUM 100-170 MMOL/L IN BLOOD AND 14-1400 MMOL/L IN UNDILUTED URINE; POTASSIUM 2-7 MMOL/L IN BLOOD AND 0.4-400 MMOL/L IN UNDILUTED URINE |
CBBL | FEATURES PROVIDED | DIGITAL DISPLAY SCREEN AND INTEGRAL PRINTER AND SELF-CALIBRATION |
FEAT | SPECIAL FEATURES | IF THE ANALYZER DOES NOT CONTAIN AN INTEGRAL PRINTER,IT SHALL BE CAPABLE OF INTERFACING W/A COMMERCIALLY AVAILABLE EXTERNAL PRINTER |
WDTH | WIDTH | 260.0 MILLIMETERS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER POTASSIUM AND SODIUM ION SELECTIVE: |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL |
CYGE | TEST SAMPLE/SPECIMEN DELIVERY DEVICE | NEEDLE/PROBE, ANALYZER ASPIRATION SYSTEM |
CYHM | TEST SAMPLE/SPECIMEN TYPE | WHOLE BLOOD,SERUM,PLASMA,AND URINE |
ACDC | CURRENT TYPE | AC |
6685-00-453-7109 (6685004537109) | 6685-01-252-3569 (6685012523569) | 6685-00-113-6576 (6685001136576) | 6650-01-255-2390 (6650012552390) |
6650-01-096-4993 (6650010964993) | 6625-01-445-2930 (6625014452930) | 6625-01-483-5099 (6625014835099) | 6645-00-225-2713 (6645002252713) |
6625-01-436-7103 (6625014367103) | 6625-00-135-7365 (6625001357365) | 6680-01-450-5074 (6680014505074) | 6625-01-073-2255 (6625010732255) |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote