Part Number : 5081-936 | Manufacturer : Agilent Technologies Inc | ||
NSN : 5950-01-082-2013 (5950010822013) | |||
Item Name : Transformer Power | CAGE Code : 1MY97 | ||
NIIN : 01-082-2013 (010822013) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 01 | Country : USA | ||
Alternate P/N: 5081936 |
Thank you for taking an interest in part number 5081-936, that of which is listed with the description Transformer Power; Manufactured by Agilent Technologies Inc and listed alongside the NSN 5950010822013, part number 5081-936 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 5081-936 | Manufacturer : Agilent Technologies Inc | ||
NSN Number : 5950-01-082-2013 (5950010822013) | |||
Item Name : Transformer Power | CAGE Code : 1MY97 | ||
NIIN : 010822013 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number 5081-936, that of which is listed with the description Transformer Power; Manufactured by Agilent Technologies Inc and listed alongside the NSN 5950010822013, part number 5081-936 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-082-2013 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010822013 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5081-936 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.7 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC POUNDS PER HOUR WET AND 120.00 AC VOLTS NOMINAL AND 220.00 AC VOLTS NOMINAL AND 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB,SOLDER LUG |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote