Part Number : 890521 | Manufacturer : Bae Systems Inc | ||
NSN : 5950-00-904-1553 (5950009041553) | |||
Item Name : Transformer Power | CAGE Code : 80249 | ||
NIIN : 00-904-1553 (009041553) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number 890521, that of which is listed with the description Transformer Power; Manufactured by Bae Systems Inc and listed alongside the NSN 5950009041553, part number 890521 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 890521 | Manufacturer : Bae Systems Inc | ||
NSN Number : 5950-00-904-1553 (5950009041553) | |||
Item Name : Transformer Power | CAGE Code : 80249 | ||
NIIN : 009041553 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number 890521, that of which is listed with the description Transformer Power; Manufactured by Bae Systems Inc and listed alongside the NSN 5950009041553, part number 890521 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-904-1553 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009041553 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
890521 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | UNABLE TO DECODE | UNABLE TO DECODE |
AAJF | UNABLE TO DECODE | UNABLE TO DECODE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 8.630 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 5.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 7.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 700.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 700.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 26.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 26.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 31.2 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 31.2 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 109.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 126.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND |
CWJS | WINDING OPERATING VOLTAGE | 23.60 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 23.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY AND NINE SECONDARIES |
PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 24 SOLDER STUD |