Part Number : CA2-B0-16-650-121-C | Manufacturer : Carling Technologies Inc | ||
NSN : 5925-01-613-5685 (5925016135685) | |||
Item Name : Circuit Breaker | CAGE Code : 73559 | ||
NIIN : 01-613-5685 (016135685) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00136 | |||
NCB Code : 01 | Country : USA | ||
Alternate P/N: CA2B016650121C |
Thank you for taking an interest in part number CA2-B0-16-650-121-C, that of which is listed with the description Circuit Breaker; Manufactured by Carling Technologies Inc and listed alongside the NSN 5925016135685, part number CA2-B0-16-650-121-C is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : CA2-B0-16-650-121-C | Manufacturer : Carling Technologies Inc | ||
NSN Number : 5925-01-613-5685 (5925016135685) | |||
Item Name : Circuit Breaker | CAGE Code : 73559 | ||
NIIN : 016135685 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number CA2-B0-16-650-121-C, that of which is listed with the description Circuit Breaker; Manufactured by Carling Technologies Inc and listed alongside the NSN 5925016135685, part number CA2-B0-16-650-121-C is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-613-5685 Item PartTypeName: CIRCUIT BREAKER | 5925 | 016135685 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CA2-B0-16-650-121-C | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 80.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 62.5 ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CXCY | Part Name Assigned By Controlling Agency | C SERIES, CIRCUIT BREAKER |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | NONTRIP FREE |
AJWX | Mounting Surface To Terminal End Distance | 2.723 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 45.0 MINIMUM AT 125 PCT AND 345.0 MAXIMUM AT 125 PCT ALL LOCATIONS |
FEAT | Special Features | USED ON BOATALT 38RP |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.