| Part Number : 8497-60-1 | Manufacturer : Cecom Lr Center | ||
| NSN : 4130-00-143-9328 (4130001439328) | |||
| Item Name : Compressor Unit | CAGE Code : 97403 | ||
| NIIN : 00-143-9328 (001439328) | |||
| FSC Code : 4130 Refrigeration and Air Conditioning Components | |||
| FSG Code : 41 Refrigeration Air Conditioning and Air Circulating Equipment | |||
| INC Code : 29305 | |||
| NCB Code : 00 | Country : USA | ||
| Alternate P/N: 8497601 | |||
Thank you for taking an interest in part number 8497-60-1, that of which is listed with the description Compressor Unit; Manufactured by Cecom Lr Center and listed alongside the NSN 4130001439328, part number 8497-60-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| Part Number : 8497-60-1 | Manufacturer : Cecom Lr Center | ||
| NSN Number : 4130-00-143-9328 (4130001439328) | |||
| Item Name : Compressor Unit | CAGE Code : 97403 | ||
| NIIN : 001439328 | |||
| FSC CODE : 4130 Refrigeration and Air Conditioning Components | |||
Thank you for taking an interest in part number 8497-60-1, that of which is listed with the description Compressor Unit; Manufactured by Cecom Lr Center and listed alongside the NSN 4130001439328, part number 8497-60-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| MRC | Criteria | Characteristic |
|---|---|---|
| AAXS | Prime Mover Cooling Medium | AIR |
| AAYD | Stage Quantity | 2 |
| MRC | Decoded Requirement | Clear Text Reply |
| FREQ | Frequency In Hertz | 400 |
| AAXP | Cooling System Design | SINGLE |
| FAAZ | Phase | THREE |
| AAXJ | Duty Cycle In Percent | 100 |
| AAYE | Refrigeration Flow Rate In Tons Per Hour | 3.2 |
| CSBH | Voltage In Volts And Current Type | 208.0 AC OR 416.0 AC |
| AKDJ | Prime Mover Type | ELECTRIC MOTOR |
| AAXX | Mounting Type | BASE |
| AAYB | Rotary Compressor Design | TWO IMPELLER |
| AAXQ | Compressed Gas Cooling Medium | AIR |
| AAXR | Compressor Cooling Medium | AIR |