Part Number : 222-10NB20-2221085 | Manufacturer : Detroit Switch Inc | ||
NSN : 5930-00-796-4020 (5930007964020) | |||
Item Name : Switch Pressure | CAGE Code : 19278 | ||
NIIN : 00-796-4020 (007964020) | |||
FSC Code : 5930 Switches | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00206 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: 22210NB202221085 |
Thank you for taking an interest in part number 222-10NB20-2221085, that of which is listed with the description Switch Pressure; Manufactured by Detroit Switch Inc and listed alongside the NSN 5930007964020, part number 222-10NB20-2221085 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 222-10NB20-2221085 | Manufacturer : Detroit Switch Inc | ||
NSN Number : 5930-00-796-4020 (5930007964020) | |||
Item Name : Switch Pressure | CAGE Code : 19278 | ||
NIIN : 007964020 | |||
FSC CODE : 5930 Switches |
Thank you for taking an interest in part number 222-10NB20-2221085, that of which is listed with the description Switch Pressure; Manufactured by Detroit Switch Inc and listed alongside the NSN 5930007964020, part number 222-10NB20-2221085 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-796-4020 Item PartTypeName: SWITCH,PRESSURE | 5930 | 007964020 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
222-10NB20-2221085 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF AND WATERTIGHT AND DUSTPROOF |
ABHP | OVERALL LENGTH | 5.188 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.937 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJB | PROOF PRESSURE | 160.00 POUNDS PER SQUARE INCH |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 7.00 TO 70.00 ACTUATION POINT POUNDS PER SQUARE INCH |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN,THREADED INTERNAL SINGLE CONNECTION |
FREQ | FREQUENCY IN HERTZ | 60.0 FOURTH VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote