Part Number : L03160 | Manufacturer : Dla Land And Maritime | ||
NSN : 5930-01-140-4344 (5930011404344) | |||
Item Name : Switch Rotary | CAGE Code : 16236 | ||
NIIN : 01-140-4344 (011404344) | |||
FSC Code : 5930 Switches | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 02134 | |||
NCB Code : 01 | Country : USA |
Thank you for taking an interest in part number L03160, that of which is listed with the description Switch Rotary; Manufactured by Dla Land And Maritime and listed alongside the NSN 5930011404344, part number L03160 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : L03160 | Manufacturer : Dla Land And Maritime | ||
NSN Number : 5930-01-140-4344 (5930011404344) | |||
Item Name : Switch Rotary | CAGE Code : 16236 | ||
NIIN : 011404344 | |||
FSC CODE : 5930 Switches |
Thank you for taking an interest in part number L03160, that of which is listed with the description Switch Rotary; Manufactured by Dla Land And Maritime and listed alongside the NSN 5930011404344, part number L03160 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-140-4344 Item Description: Switch Rotary | 5930 | 011404344 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
L03160 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AFBH | Individual Section Quantity | 9 |
AFCQ | Knob Manufacturer Code | 82121 |
FEAT | Special Features | ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L03160; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
AKPY | Throw Quantity | 3 EACH SECTION REAR |
CSLC | Switch Actuator Positioning Increment | 90.0 DEGREES SINGLE ACTUATOR |
ABWV | Shaft Diameter | 0.375 INCHES NOMINAL SINGLE ACTUATOR |
CQYJ | Mounting Facility Pattern | TWO POSITION IN-LINE 2ND MOUNTING FACILITY |
AKPX | Pole Quantity | 1 EACH SECTION REAR |
CQYJ | Mounting Facility Pattern | FOUR POSITION RECTANGULAR 1ST MOUNTING FACILITY |
CBBL | Features Provided | ACTUATOR KNOB |
AFDS | Longest Horizontal Distance Between Mounting Centers | 3.812 INCHES NOMINAL 2ND MOUNTING FACILITY |
AAJD | Thread Class | 2B 2ND MOUNTING FACILITY |
ABNB | First Flat Length | 1.375 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | Flat Height | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
AAJD | Thread Class | 2B 1ST MOUNTING FACILITY |
ZZZY | Reference Number Differentiating Characteristics | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |
AXGY | Mounting Method | BRACKET 1ST MOUNTING FACILITY AND THREADED HOLE 1ST MOUNTING FACILITY |
THSD | Thread Series Designator | UNC 1ST MOUNTING FACILITY |
MRC | Decoded Requirement | Clear Text Reply |
ABHP | Overall Length | 8.000 INCHES NOMINAL |
CRTL | Criticality Code Justification | FEAT |
CQJX | Nominal Thread Size | 0.250 INCHES 1ST MOUNTING FACILITY |
CRJH | Switch Actuator Indexing Position Quantity | 4 SINGLE ACTUATOR |
CTDN | Switch Actuator Stop Device Type | FIXED STOP SINGLE ACTUATOR |
AJZE | Switch Contact Basic Design | NONPILE-UP SYMMETRICAL |
ABXF | Shaft Length | 1.375 INCHES NOMINAL SINGLE ACTUATOR |
CQMK | Contact Voltage Rating In Volts | 125.0 AC AT SEA LEVEL |
AFDS | Longest Horizontal Distance Between Mounting Centers | 2.281 INCHES NOMINAL 1ST MOUNTING FACILITY |
AFDV | Longest Vertical Distance Between Mounting Centers | 2.281 INCHES NOMINAL 1ST MOUNTING FACILITY |
ABMK | Overall Width | 4.375 INCHES NOMINAL |
CTHF | Contact Load Current Rating | 10.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
CRSJ | Shaft Type | ROUND, FLATTED, THREADED HOLE SINGLE ACTUATOR |
CSCF | Terminal Type | TAB W/SCREW |
AEBV | Unthreaded Mounting Hole Diameter | 0.312 INCHES NOMINAL 2ND MOUNTING FACILITY |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS 9TH SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 6TH SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 3RD SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 1ST SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 8TH SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 4TH SECTION REAR |
AXGY | Mounting Method | BRACKET 2ND MOUNTING FACILITY AND UNTHREADED HOLE 2ND MOUNTING FACILITY |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 2ND SECTION REAR |
CMLP | Thread Quantity Per Inch | 20 1ST MOUNTING FACILITY |
STYL | Style Designator | TAP, CIRCUIT SELECTOR |
CSHW | Contact Switching Action | MAKES BEFORE BREAKS 7TH SECTION REAR |
CSHW | Contact Switching Action | BREAKS BEFORE MAKES 5TH SECTION REAR |
ABFE | Hazardous Locations/Environmental Protection | DUSTPROOF |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.