Part Number : 800-01381 | Manufacturer : Draeger Safety Inc | ||
NSN : 6665-01-353-3785 (6665013533785) | |||
Item Name : Detector Gas | CAGE Code : 53833 | ||
NIIN : 01-353-3785 (013533785) | |||
FSC Code : 6665 Hazard Detecting Instruments And Apparatus | |||
FSG Code : 66 Instruments and Laboratory Equipment | |||
INC Code : 37401 | |||
NCB Code : 01 | Country : USA | ||
Alternate P/N: 80001381 |
Thank you for taking an interest in part number 800-01381, that of which is listed with the description Detector Gas; Manufactured by Draeger Safety Inc and listed alongside the NSN 6665013533785, part number 800-01381 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 800-01381 | Manufacturer : Draeger Safety Inc | ||
NSN Number : 6665-01-353-3785 (6665013533785) | |||
Item Name : Detector Gas | CAGE Code : 53833 | ||
NIIN : 013533785 | |||
FSC CODE : 6665 Hazard Detecting Instruments And Apparatus |
Thank you for taking an interest in part number 800-01381, that of which is listed with the description Detector Gas; Manufactured by Draeger Safety Inc and listed alongside the NSN 6665013533785, part number 800-01381 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 5.000 INCHES NOMINAL |
AMRZ | Detecting Element Detachability | INTEGRAL |
AMSL | Preamplifier | NOT INCLUDED |
AMSM | Photomultiplier | NOT INCLUDED |
AMRX | Detecting Element Type | CHEMICAL REACTION |
ADAV | Overall Diameter | 0.833 INCHES NOMINAL |
ADTV | Case Material | GLASS |
FEAT | Special Features | GRADUATED,DIRECT-READING GLASS DIFFUSION TUBE; CARBON DIOXIDE SAMPLES ARE TAKEN AT A CONSTANT RATE AND DIFFUSED INTO THE TUBE WHERE THEY UNDERGO A COLORIMETRIC REACTION; MEASURES TIME-WEIGHTED AVERAGE CONCENTRATIONS FOR PERIODS UP TO 8 HOURS; ON SPOT RESULTS; NO INSTRUMENTS NEEDED; 500 TO 20,000 PPM X H; 65 TO 2,500 PPM MAX DURING 8 HOURS |
MRC | Decoded Requirement | Clear Text Reply |