Part Number : AM0666MG6SW50-250VRC25-208V60C4 | Manufacturer : Eaton Corporation | ||
NSN : 5925-00-071-9844 (5925000719844) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 00-071-9844 (000719844) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00136 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: AM0666MG6SW50250VRC25208V60C4 |
Thank you for taking an interest in part number AM0666MG6SW50-250VRC25-208V60C4, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925000719844, part number AM0666MG6SW50-250VRC25-208V60C4 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : AM0666MG6SW50-250VRC25-208V60C4 | Manufacturer : Eaton Corporation | ||
NSN Number : 5925-00-071-9844 (5925000719844) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 000719844 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number AM0666MG6SW50-250VRC25-208V60C4, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925000719844, part number AM0666MG6SW50-250VRC25-208V60C4 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-071-9844 Item PartTypeName: CIRCUIT BREAKER | 5925 | 000719844 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM0666MG6-25-208VAC60C4 | 2 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.960 INCHES MINIMUM AND 3.040 INCHES MAXIMUM |
ADTV | UNABLE TO DECODE | UNABLE TO DECODE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.539 INCHES MINIMUM AND 2.683 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 4 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES AC FOURTH LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES AC THIRD LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 208.0 AC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 208.0 AC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 208.0 AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC FOURTH LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC THIRD LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FOURTH LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT THIRD LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FOURTH LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FOURTH LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FOURTH LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 THIRD LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,THREE,AND FOUR LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP FOURTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT FOURTH LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CTJS | UNPACKAGED UNIT WEIGHT | 13.000 OUNCES NOMINAL |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | POLE ONE IS SWITCH ONLY |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote