Part Number : JC3-A3-15-2 | Manufacturer : Eaton Corporation | ||
NSN : 5925-00-336-1989 (5925003361989) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 00-336-1989 (003361989) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00136 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: JC3A3152 |
Thank you for taking an interest in part number JC3-A3-15-2, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925003361989, part number JC3-A3-15-2 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : JC3-A3-15-2 | Manufacturer : Eaton Corporation | ||
NSN Number : 5925-00-336-1989 (5925003361989) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 003361989 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number JC3-A3-15-2, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925003361989, part number JC3-A3-15-2 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
ABXD | Bushing Length | 0.098 INCHES MINIMUM AND 0.162 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, MALE |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM |
ADAQ | Body Length | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.528 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRQ | Reset Method | MANUAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM |