Part Number : AM33MG6-30-250-4-60 | Manufacturer : Eaton Corporation | ||
NSN : 5925-00-933-6041 (5925009336041) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 00-933-6041 (009336041) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: AM33MG630250460 |
Thank you for taking an interest in part number AM33MG6-30-250-4-60, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925009336041, part number AM33MG6-30-250-4-60 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : AM33MG6-30-250-4-60 | Manufacturer : Eaton Corporation | ||
NSN Number : 5925-00-933-6041 (5925009336041) | |||
Item Name : Circuit Breaker | CAGE Code : 74193 | ||
NIIN : 009336041 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number AM33MG6-30-250-4-60, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925009336041, part number AM33MG6-30-250-4-60 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | EXPLOSION RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADAT | Body Width | 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
APNQ | Arc Quenching Method | AIR |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 11.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.