| Part Number : KD1-9 | Manufacturer : Eaton Corporation | ||
| NSN : 5925-01-205-2851 (5925012052851) | |||
| Item Name : Circuit Breaker | CAGE Code : 74193 | ||
| NIIN : 01-205-2851 (012052851) | |||
| FSC Code : 5925 Circuit Breakers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 00136 | |||
| NCB Code : 01 | Country : USA | ||
| Alternate P/N: KD19 | |||
Thank you for taking an interest in part number KD1-9, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925012052851, part number KD1-9 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
|
3s group inc
CAGE Code: 07CN0 |
1spatial ltd
CAGE Code: U3518 |
|
25 canadian forces supply depot
CAGE Code: 35637 |
1 source electronics inc
CAGE Code: 551K1 |
|
3m health care service center
CAGE Code: 0UTW7 |
3d safety services pty ltd
CAGE Code: Z2JB4 |
|
4fastplumber llc
CAGE Code: 4P0W6 |
2is inc
CAGE Code: 1ZKD0 |
|
28eme groupe geographique
CAGE Code: FAR17 |
360 tents l l c
CAGE Code: 4CT45 |
|
3m purification pty limited
CAGE Code: Z5295 |
3m medical imaging
CAGE Code: 0ZRE5 |
|
400hz repair
CAGE Code: 03MS6 |
3m deutschland gmbh
CAGE Code: D2607 |
|
2mb international
CAGE Code: FA7N3 |
| Part Number : KD1-9 | Manufacturer : Eaton Corporation | ||
| NSN Number : 5925-01-205-2851 (5925012052851) | |||
| Item Name : Circuit Breaker | CAGE Code : 74193 | ||
| NIIN : 012052851 | |||
| FSC CODE : 5925 Circuit Breakers | |||
Thank you for taking an interest in part number KD1-9, that of which is listed with the description Circuit Breaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925012052851, part number KD1-9 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-205-2851 Item PartTypeName: CIRCUIT BREAKER | 5925 | 012052851 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 7822070-025 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ADAQ | BODY LENGTH | 1.775 INCHES NOMINAL |
| ADAV | OVERALL DIAMETER | 0.750 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLIP |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 9.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 200.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| CPRW | ACTUATOR FUNCTION | RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.500 MINIMUM AT 200 PCT AND 12.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| CWJK | CASE MATERIAL | PLASTIC |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT,MALE |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.