Part Number : HM2-224-012 | Manufacturer : Eaton Corporation | ||
NSN : 5925-01-396-1121 (5925013961121) | |||
Item Name : Circuitbreaker | CAGE Code : 74193 | ||
NIIN : 01-396-1121 (013961121) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00136 | |||
NCB Code : 01 | Country : USA | ||
Alternate P/N: HM2224012 |
Thank you for taking an interest in part number HM2-224-012, that of which is listed with the description Circuitbreaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925013961121, part number HM2-224-012 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : HM2-224-012 | Manufacturer : Eaton Corporation | ||
NSN Number : 5925-01-396-1121 (5925013961121) | |||
Item Name : Circuitbreaker | CAGE Code : 74193 | ||
NIIN : 013961121 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number HM2-224-012, that of which is listed with the description Circuitbreaker; Manufactured by Eaton Corporation and listed alongside the NSN 5925013961121, part number HM2-224-012 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-396-1121 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013961121 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP12-R-87057-012 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS AND 1.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES NOMINAL |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 0.5 AC AND 0.5 DC |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
CPRW | Actuator Function | TRIP-RESET |
CSWP | Switch Voltage Rating And Type In Volts | 120.0 AC AND 50.0 DC |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.562 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 AC ALL LOCATIONS AND 500.0 DC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |