| Part Number : 1C1804-118 | Manufacturer : General Electric Company | ||
| NSN : 5950-00-552-0891 (5950005520891) | |||
| Item Name : Transformer Power | CAGE Code : 24446 | ||
| NIIN : 00-552-0891 (005520891) | |||
| FSC Code : 5950 Coils and Transformers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 32496 | |||
| NCB Code : 00 | Country : USA | ||
| Alternate P/N: 1C1804118 | |||
Thank you for taking an interest in part number 1C1804-118, that of which is listed with the description Transformer Power; Manufactured by General Electric Company and listed alongside the NSN 5950005520891, part number 1C1804-118 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| Part Number : 1C1804-118 | Manufacturer : General Electric Company | ||
| NSN Number : 5950-00-552-0891 (5950005520891) | |||
| Item Name : Transformer Power | CAGE Code : 24446 | ||
| NIIN : 005520891 | |||
| FSC CODE : 5950 Coils and Transformers | |||
Thank you for taking an interest in part number 1C1804-118, that of which is listed with the description Transformer Power; Manufactured by General Electric Company and listed alongside the NSN 5950005520891, part number 1C1804-118 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-552-0891 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005520891 | P | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| R-7A | 6 | 1 | C | 9 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP0.188 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL2.750 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.187 INCHES NOMINAL3.187 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED,DOUBLE SHELLPARTIALLY INCLOSED,DOUBLE SHELL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
| CQLC | UNABLE TO DECODE | UNABLE TO DECODE |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY12.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 12.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 30.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY600.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 600.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |