Part Number : CD3-C3-DU-60-240-1 | Manufacturer : Heinemann Electric Co Inc | ||
NSN : 5925-01-592-9196 (5925015929196) | |||
Item Name : Circuitbreaker | CAGE Code : L3330 | ||
NIIN : 01-592-9196 (015929196) | |||
FSC Code : 5925 Circuit Breakers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00136 | |||
NCB Code : 01 | Country : USA | ||
Alternate P/N: CD3C3DU602401 |
Thank you for taking an interest in part number CD3-C3-DU-60-240-1, that of which is listed with the description Circuitbreaker; Manufactured by Heinemann Electric Co Inc and listed alongside the NSN 5925015929196, part number CD3-C3-DU-60-240-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : CD3-C3-DU-60-240-1 | Manufacturer : Heinemann Electric Co Inc | ||
NSN Number : 5925-01-592-9196 (5925015929196) | |||
Item Name : Circuitbreaker | CAGE Code : L3330 | ||
NIIN : 015929196 | |||
FSC CODE : 5925 Circuit Breakers |
Thank you for taking an interest in part number CD3-C3-DU-60-240-1, that of which is listed with the description Circuitbreaker; Manufactured by Heinemann Electric Co Inc and listed alongside the NSN 5925015929196, part number CD3-C3-DU-60-240-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-592-9196 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015929196 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CD3-C3-DU-60-240-1 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 60.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.219 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
MRC | Decoded Requirement | Clear Text Reply |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.026 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | NONTRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 3.138 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 SCREW |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 3.485 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 5.125 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 3.547 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.026 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 35.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 150.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT POLE ONE AND AT POLE TWO AND AT POLE THREE |