| Part Number : 25N215490 98738 | Manufacturer : Herley Chicago | ||
| NSN : 5950-00-117-7843 (5950001177843) | |||
| Item Name : Transformer Power | CAGE Code : 98738 | ||
| NIIN : 00-117-7843 (001177843) | |||
| FSC Code : 5950 Coils and Transformers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 32496 | |||
| NCB Code : 00 | Country : USA | ||
Thank you for taking an interest in part number 25N215490 98738, that of which is listed with the description Transformer Power; Manufactured by Herley Chicago and listed alongside the NSN 5950001177843, part number 25N215490 98738 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
|
394 test maintenance squadron sac
CAGE Code: 33044 |
21st century optics inc
CAGE Code: 0TN38 |
|
2709th af vehicle control group
CAGE Code: 10994 |
3m co health care services sales
CAGE Code: 0Z2D0 |
|
3m alaska
CAGE Code: 0NZU5 |
3m united kingdom plc
CAGE Code: K0993,K8767 |
|
3m co electronics and communications
CAGE Code: 0ESF3,17325,70209,8M369 |
1st solutions inc
CAGE Code: 0FY35,0TU77 |
|
3g shielding specialties lp
CAGE Code: 7PCU6 |
2mb international
CAGE Code: FA7N3 |
|
1 source electronics inc
CAGE Code: 551K1 |
4fastplumber llc
CAGE Code: 4P0W6 |
|
24 hour distributors
CAGE Code: 12136,3WKM0 |
3m espana sa
CAGE Code: 0211B,H7034 |
|
3d
CAGE Code: 0WY47 |
| Part Number : 25N215490 98738 | Manufacturer : Herley Chicago | ||
| NSN Number : 5950-00-117-7843 (5950001177843) | |||
| Item Name : Transformer Power | CAGE Code : 98738 | ||
| NIIN : 001177843 | |||
| FSC CODE : 5950 Coils and Transformers | |||
Thank you for taking an interest in part number 25N215490 98738, that of which is listed with the description Transformer Power; Manufactured by Herley Chicago and listed alongside the NSN 5950001177843, part number 25N215490 98738 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-117-7843 Item PartTypeName: TRANSFORMER,POWER | 5950 | 001177843 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| TT1-13124 | 6 | 9 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAJF | UNABLE TO DECODE | UNABLE TO DECODE |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 5.000 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 4.859 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 1.750 INCHES NOMINAL |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 5.000 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.750 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 3.562 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 116.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 1.36 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 247.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.10 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 SOLDER STUD |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote