Part Number : 203974-1 | Manufacturer : Honeywell International Inc | ||
NSN : 5930-00-091-9254 (5930000919254) | |||
Item Name : Switch Thermostatic | CAGE Code : 70210 | ||
NIIN : 00-091-9254 (000919254) | |||
FSC Code : 5930 Switches | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00451 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: 2039741 |
Thank you for taking an interest in part number 203974-1, that of which is listed with the description Switch Thermostatic; Manufactured by Honeywell International Inc and listed alongside the NSN 5930000919254, part number 203974-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 203974-1 | Manufacturer : Honeywell International Inc | ||
NSN Number : 5930-00-091-9254 (5930000919254) | |||
Item Name : Switch Thermostatic | CAGE Code : 70210 | ||
NIIN : 000919254 | |||
FSC CODE : 5930 Switches |
Thank you for taking an interest in part number 203974-1, that of which is listed with the description Switch Thermostatic; Manufactured by Honeywell International Inc and listed alongside the NSN 5930000919254, part number 203974-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-091-9254 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 000919254 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
21738 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEVT | CAPILLARY TUBE LENGTH | 2.000 INCHES MINIMUM AND 2.300 INCHES MAXIMUM |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CSCF | TERMINAL TYPE | CONNECTOR,RECEPTACLE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 400.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote