Part Number : 5945PL1368746 | Manufacturer : Inspektorat Wsparcia Sil Zbrojnych | ||
NSN : 5945-00-809-7480 (5945008097480) | |||
Item Name : Relay Electromagnetic | CAGE Code : 9009H | ||
NIIN : 00-809-7480 (008097480) | |||
FSC Code : 5945 Relays and Solenoids | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32512 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number 5945PL1368746, that of which is listed with the description Relay Electromagnetic; Manufactured by Inspektorat Wsparcia Sil Zbrojnych and listed alongside the NSN 5945008097480, part number 5945PL1368746 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 5945PL1368746 | Manufacturer : Inspektorat Wsparcia Sil Zbrojnych | ||
NSN Number : 5945-00-809-7480 (5945008097480) | |||
Item Name : Relay Electromagnetic | CAGE Code : 9009H | ||
NIIN : 008097480 | |||
FSC CODE : 5945 Relays and Solenoids |
Thank you for taking an interest in part number 5945PL1368746, that of which is listed with the description Relay Electromagnetic; Manufactured by Inspektorat Wsparcia Sil Zbrojnych and listed alongside the NSN 5945008097480, part number 5945PL1368746 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-809-7480 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 008097480 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
FC400-117 | 3 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.156 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.531 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.147 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 7.219 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.844 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC AND 6.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS25327 GOVERNMENT STANDARD |
ABHP | OVERALL LENGTH | 2.187 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | SPECIFIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |