Part Number : R235A062-5 | Manufacturer : Instrument Systems Corp | ||
NSN : 5905-00-543-0627 (5905005430627) | |||
Item Name : Resistor Fixed Wire Wound Nonind | CAGE Code : 09966 | ||
NIIN : 00-543-0627 (005430627) | |||
FSC Code : 5905 Resistors | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 00010 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: R235A0625 |
Thank you for taking an interest in part number R235A062-5, that of which is listed with the description Resistor Fixed Wire Wound Nonind; Manufactured by Instrument Systems Corp and listed alongside the NSN 5905005430627, part number R235A062-5 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : R235A062-5 | Manufacturer : Instrument Systems Corp | ||
NSN Number : 5905-00-543-0627 (5905005430627) | |||
Item Name : Resistor Fixed Wire Wound Nonind | CAGE Code : 09966 | ||
NIIN : 005430627 | |||
FSC CODE : 5905 Resistors |
Thank you for taking an interest in part number R235A062-5, that of which is listed with the description Resistor Fixed Wire Wound Nonind; Manufactured by Instrument Systems Corp and listed alongside the NSN 5905005430627, part number R235A062-5 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-543-0627 Item PartTypeName: RESISTOR,FIXED,WIRE WOUND | 5905 | 005430627 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
F269-5 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
AAPP | ELECTRICAL RESISTANCE | 0.0156 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2.000 TO 2.000 |
AAQF | UNABLE TO DECODE | UNABLE TO DECODE |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
AAQZ | UNABLE TO DECODE | UNABLE TO DECODE |
AARB | UNABLE TO DECODE | UNABLE TO DECODE |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.200 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.475 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.639 FREE AIR |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CSCF | TERMINAL TYPE | WIRE LEAD |
FEAT | SPECIAL FEATURES | TWO NO. 24 AWG TERMINALS AND TWO NO. 20 AWG TERMINALS |
SPCL | SPECIAL TEST FEATURES | STEADY STATE COND 6.4 AMP AT 100 MV; GLOW COND ONE 19.2 AMP AT 5.8 W AT 200 MILLISECONDS MAX; LOW COND TWO 64.0 AMP AT 64.0 W AT 50 MILLISECONDS MAX |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 09966-R235A062 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.