| Part Number : 3023509-602-101 | Manufacturer : Lockheed Martin Corporation | ||
| NSN : 5925-00-432-9460 (5925004329460) | |||
| Item Name : Circuit Breaker | CAGE Code : 99696 | ||
| NIIN : 00-432-9460 (004329460) | |||
| FSC Code : 5925 Circuit Breakers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 00136 | |||
| NCB Code : 00 | Country : USA | ||
| Alternate P/N: 3023509602101 | |||
Thank you for taking an interest in part number 3023509-602-101, that of which is listed with the description Circuit Breaker; Manufactured by Lockheed Martin Corporation and listed alongside the NSN 5925004329460, part number 3023509-602-101 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| Part Number : 3023509-602-101 | Manufacturer : Lockheed Martin Corporation | ||
| NSN Number : 5925-00-432-9460 (5925004329460) | |||
| Item Name : Circuit Breaker | CAGE Code : 99696 | ||
| NIIN : 004329460 | |||
| FSC CODE : 5925 Circuit Breakers | |||
Thank you for taking an interest in part number 3023509-602-101, that of which is listed with the description Circuit Breaker; Manufactured by Lockheed Martin Corporation and listed alongside the NSN 5925004329460, part number 3023509-602-101 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN | 
|---|---|---|---|---|---|---|
| 5925-00-432-9460 Item PartTypeName: CIRCUIT BREAKER | 5925 | 004329460 | P | |||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | ||||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC | 
| 3023509-602-101 | 2 | 2 | 5 | 
| MRC | Criteria | Characteristic | 
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE | 
| ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL | 
| ADAT | BODY WIDTH | 2.250 INCHES NOMINAL | 
| ADTV | UNABLE TO DECODE | UNABLE TO DECODE | 
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.938 INCHES NOMINAL | 
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL | 
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL | 
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL | 
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED | 
| AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL | 
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.611 INCHES NOMINAL | 
| AKPX | POLE QUANTITY | 3 | 
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT | 
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE | 
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE | 
| CMLP | THREAD QUANTITY PER INCH | 32 | 
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS | 
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS | 
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS | 
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS | 
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS | 
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS | 
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS | 
| CPRQ | RESET METHOD | MANUAL | 
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE | 
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE | 
| CPRW | ACTUATOR FUNCTION | TRIP-RESET | 
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE | 
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED | 
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS | 
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES | 
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.500 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS | 
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT | 
| CTJS | UNPACKAGED UNIT WEIGHT | 14.000 OUNCES NOMINAL | 
| CWJK | CASE MATERIAL | PLASTIC | 
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS | 
| THSD | THREAD SERIES DESIGNATOR | UNC | 
| TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD | 