Part Number : 10132732 | Manufacturer : Nimikkeistokeskus Ncb Finland | ||
NSN : 5950-01-055-3984 (5950010553984) | |||
Item Name : Transformer Power | CAGE Code : A486G | ||
NIIN : 01-055-3984 (010553984) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 01 | Country : USA |
Thank you for taking an interest in part number 10132732, that of which is listed with the description Transformer Power; Manufactured by Nimikkeistokeskus Ncb Finland and listed alongside the NSN 5950010553984, part number 10132732 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 10132732 | Manufacturer : Nimikkeistokeskus Ncb Finland | ||
NSN Number : 5950-01-055-3984 (5950010553984) | |||
Item Name : Transformer Power | CAGE Code : A486G | ||
NIIN : 010553984 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number 10132732, that of which is listed with the description Transformer Power; Manufactured by Nimikkeistokeskus Ncb Finland and listed alongside the NSN 5950010553984, part number 10132732 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-055-3984 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010553984 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C15899 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.177 INCHES MINIMUM SINGLE GROUP AND 0.197 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.215 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.235 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CBME | UNABLE TO DECODE | UNABLE TO DECODE |
CRBZ | WINDING OPERATING CURRENT | 4.03 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 541.9 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 689.6 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 11.0 WATTS SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 14.0 WATTS SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 25.0 WATTS SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 13 EYELET |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote