| Part Number : 44-200-P10-SI-043-800-1 | Manufacturer : Oakland Industries Ltd | ||
| NSN : 5925-01-259-3597 (5925012593597) | |||
| Item Name : Circuit Breaker | CAGE Code : 06402 | ||
| NIIN : 01-259-3597 (012593597) | |||
| FSC Code : 5925 Circuit Breakers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 00136 | |||
| NCB Code : 01 | Country : USA | ||
| Alternate P/N: 44200P10SI0438001 | |||
Thank you for taking an interest in part number 44-200-P10-SI-043-800-1, that of which is listed with the description Circuit Breaker; Manufactured by Oakland Industries Ltd and listed alongside the NSN 5925012593597, part number 44-200-P10-SI-043-800-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
|
3m medical imaging
CAGE Code: 0ZRE5 |
2001 micro systemation ab
CAGE Code: SK396 |
|
10zig technology inc
CAGE Code: 49E04 |
3m company communication markets
CAGE Code: 0VGY3 |
|
3m co abrasive systems division
CAGE Code: 078Z1 |
3m industrial adhesives and tapes
CAGE Code: 0XV20 |
|
3m canada inc
CAGE Code: 09581,0GSY9,L2266 |
400hz repair
CAGE Code: 03MS6 |
|
2kr systems llc
CAGE Code: 730Z2 |
24 hour distributors
CAGE Code: 12136,3WKM0 |
|
3w interface corp
CAGE Code: 4V367 |
4 c s welding lab inc
CAGE Code: 59685 |
|
20 10 products inc
CAGE Code: 09KC9 |
4 s mfg
CAGE Code: 0D9C0 |
|
3m touch systems canada ltd
CAGE Code: L0831 |
| Part Number : 44-200-P10-SI-043-800-1 | Manufacturer : Oakland Industries Ltd | ||
| NSN Number : 5925-01-259-3597 (5925012593597) | |||
| Item Name : Circuit Breaker | CAGE Code : 06402 | ||
| NIIN : 012593597 | |||
| FSC CODE : 5925 Circuit Breakers | |||
Thank you for taking an interest in part number 44-200-P10-SI-043-800-1, that of which is listed with the description Circuit Breaker; Manufactured by Oakland Industries Ltd and listed alongside the NSN 5925012593597, part number 44-200-P10-SI-043-800-1 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-259-3597 Item PartTypeName: CIRCUIT BREAKER | 5925 | 012593597 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 44-200-P10-SI-043.800-1 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABXD | BUSHING LENGTH | 6.5 MILLIMETERS NOMINAL |
| ADAQ | BODY LENGTH | 19.8 MILLIMETERS NOMINAL |
| ADAT | BODY WIDTH | 15.8 MILLIMETERS NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 14.0 MILLIMETERS NOMINAL |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 43.5 MILLIMETERS NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| CMLP | THREAD QUANTITY PER INCH | 27 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 MILLIAMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 28.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 100.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 11.000 MINIMUM AT 200 PCT AND 60.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 73.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION |
| CRTK | SWITCH TERMINAL TYPE | QUICK DISCONNECT,MALE |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 3.0 DC |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 28.0 DC |
| CWJK | CASE MATERIAL | PLASTIC |
| FEAT | SPECIAL FEATURES | MARKED 1 AMP FOR TRAINING ONLY |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT,MALE |