Part Number : H060 | Manufacturer : Sensor Systems Inc | ||
NSN : 5905-00-789-5927 (5905007895927) | |||
Item Name : Resistor Variable Nonwire Wound | CAGE Code : 04454 | ||
NIIN : 00-789-5927 (007895927) | |||
FSC Code : 5905 Resistors | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 37407 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number H060, that of which is listed with the description Resistor Variable Nonwire Wound; Manufactured by Sensor Systems Inc and listed alongside the NSN 5905007895927, part number H060 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : H060 | Manufacturer : Sensor Systems Inc | ||
NSN Number : 5905-00-789-5927 (5905007895927) | |||
Item Name : Resistor Variable Nonwire Wound | CAGE Code : 04454 | ||
NIIN : 007895927 | |||
FSC CODE : 5905 Resistors |
Thank you for taking an interest in part number H060, that of which is listed with the description Resistor Variable Nonwire Wound; Manufactured by Sensor Systems Inc and listed alongside the NSN 5905007895927, part number H060 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-789-5927 Item PartTypeName: RESISTORVARIABLENONWIRE WOUND | 5905 | 007895927 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
H060 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 7 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAVL | PILOT DIAMETER | 0.9688 INCHES MAXIMUM |
AAVM | PILOT LENGTH | 0.0620 INCHES NOMINAL |
ABNC | FLAT HEIGHT | 0.104 INCHES MINIMUM AND 0.106 INCHES MAXIMUM |
ABPA | UNDERCUT DIAMETER | 0.969 INCHES MAXIMUM |
ABPC | UNDERCUT WIDTH | 0.0570 INCHES MINIMUM |
ABWV | SHAFT DIAMETER | 0.1242 INCHES MINIMUM AND 0.1247 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.437 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.880 INCHES NOMINAL |
AEDA | MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND,FLATTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 KILOHMS 1ST SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS 6TH SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 40.0 KILOHMS 3RD SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 7.5 PERCENT,RATED AMPERES C AND BETTER V.G. STEPPING |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.25 TO 0.25 1ST SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.00/1.00 2ND SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.00/1.00 4TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50 TO 1.50 5TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.50/1.50 6TH SECTION |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -2.00 TO 2.00 7TH SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 ALL SECTIONS |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS EQUATION |
TEST | TEST DATA DOCUMENT | 97942-577R900 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 30 TURRET |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED |
ABNB | FIRST FLAT LENGTH | 0.377 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.062 INCHES NOMINAL |
AECZ | MOUNTING LIP DIAMETER | 1.0620 INCHES NOMINAL |
AXGY | MOUNTING METHOD | CLAMP RING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.0 PERCENT,RATED AMPERES C FLOORING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 PERCENT,RATED AMPERES C DROP SIDING |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 7.5 PERCENT,RATED AMPERES C AND BETTER INDUSTRIAL CLEARS |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.65 TO 0.65 3RD SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 ALL SECTIONS |
CRGM | FUNCTION CONFORMITY PER SECTION | ALL SECTIONS ABSOLUTE CONFORMITY |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 25.0 ALL SECTIONS |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote