Part Number : DU-1-4 | Manufacturer : Signal Transformer Co Inc | ||
NSN : 5950-00-518-7522 (5950005187522) | |||
Item Name : Transformer Power | CAGE Code : 08779 | ||
NIIN : 00-518-7522 (005187522) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 00 | Country : USA | ||
Alternate P/N: DU14 |
Thank you for taking an interest in part number DU-1-4, that of which is listed with the description Transformer Power; Manufactured by Signal Transformer Co Inc and listed alongside the NSN 5950005187522, part number DU-1-4 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : DU-1-4 | Manufacturer : Signal Transformer Co Inc | ||
NSN Number : 5950-00-518-7522 (5950005187522) | |||
Item Name : Transformer Power | CAGE Code : 08779 | ||
NIIN : 005187522 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number DU-1-4, that of which is listed with the description Transformer Power; Manufactured by Signal Transformer Co Inc and listed alongside the NSN 5950005187522, part number DU-1-4 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-518-7522 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005187522 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DU-1/4 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPENOPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CQLC | UNABLE TO DECODE | UNABLE TO DECODE |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VO |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 120.00 A |
PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote