| Part Number : DU-1 2 | Manufacturer : Signal Transformer Co Inc | ||
| NSN : 5950-00-520-2693 (5950005202693) | |||
| Item Name : Transformer Power | CAGE Code : 08779 | ||
| NIIN : 00-520-2693 (005202693) | |||
| FSC Code : 5950 Coils and Transformers | |||
| FSG Code : 59 Electrical and Electronic Equipment Components | |||
| INC Code : 32496 | |||
| NCB Code : 00 | Country : USA | ||
| Alternate P/N: DU12 | |||
Thank you for taking an interest in part number DU-1 2, that of which is listed with the description Transformer Power; Manufactured by Signal Transformer Co Inc and listed alongside the NSN 5950005202693, part number DU-1 2 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| Part Number : DU-1 2 | Manufacturer : Signal Transformer Co Inc | ||
| NSN Number : 5950-00-520-2693 (5950005202693) | |||
| Item Name : Transformer Power | CAGE Code : 08779 | ||
| NIIN : 005202693 | |||
| FSC CODE : 5950 Coils and Transformers | |||
Thank you for taking an interest in part number DU-1 2, that of which is listed with the description Transformer Power; Manufactured by Signal Transformer Co Inc and listed alongside the NSN 5950005202693, part number DU-1 2 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-520-2693 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005202693 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| DU-1/2 | 2 | 9 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
| ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.5 KILOVOLT-AMPERE SINGLE COMPONENT0.5 KILOVOLT-AMPERE SINGLE COMPONENT0.5 KILOVOLT-AMPERE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | OPENOPENOPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
| CQLC | UNABLE TO DECODE | UNABLE TO DECODE |
| CRBZ | WINDING OPERATING CURRENT | 4.6 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
| TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |