Part Number : 11570 | Manufacturer : Sora Power Inc | ||
NSN : 5950-00-324-0267 (5950003240267) | |||
Item Name : Transformer Power | CAGE Code : 55196 | ||
NIIN : 00-324-0267 (003240267) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number 11570, that of which is listed with the description Transformer Power; Manufactured by Sora Power Inc and listed alongside the NSN 5950003240267, part number 11570 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 11570 | Manufacturer : Sora Power Inc | ||
NSN Number : 5950-00-324-0267 (5950003240267) | |||
Item Name : Transformer Power | CAGE Code : 55196 | ||
NIIN : 003240267 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number 11570, that of which is listed with the description Transformer Power; Manufactured by Sora Power Inc and listed alongside the NSN 5950003240267, part number 11570 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-324-0267 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003240267 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
860923 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.380 INCHES NOMINAL SINGLE GROUP0.380 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 15.0 KILOHERTZ NOMINAL SINGLE COMPONENT15.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAU | BODY HEIGHT | 1.780 INCHES MAXIMUM1.780 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY134.33 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY28.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY4.24 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | THIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST OF ONE PRIMARY AND SEVEN SECONDARY WINDINGSTHIRD AND FOURTH SECONDARIES HAVE THE CURRENT AND VOLTAGE RECTIFIED; ALSO THE TRANSFORMER CONSIST O |
PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB,SOLDER LUG |