Part Number : 808953 | Manufacturer : Teledyne Controls Llc | ||
NSN : 5905-00-980-0830 (5905009800830) | |||
Item Name : Resistor Variable Wire Wound Pre | CAGE Code : 98571 | ||
NIIN : 00-980-0830 (009800830) | |||
FSC Code : 5905 Resistors | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 37408 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number 808953, that of which is listed with the description Resistor Variable Wire Wound Pre; Manufactured by Teledyne Controls Llc and listed alongside the NSN 5905009800830, part number 808953 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 808953 | Manufacturer : Teledyne Controls Llc | ||
NSN Number : 5905-00-980-0830 (5905009800830) | |||
Item Name : Resistor Variable Wire Wound Pre | CAGE Code : 98571 | ||
NIIN : 009800830 | |||
FSC CODE : 5905 Resistors |
Thank you for taking an interest in part number 808953, that of which is listed with the description Resistor Variable Wire Wound Pre; Manufactured by Teledyne Controls Llc and listed alongside the NSN 5905009800830, part number 808953 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-980-0830 Item PartTypeName: RESISTOR,VARIABLE,WIRE WOUND,PRE | 5905 | 009800830 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
C | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
808953 | C | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 3 |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAVL | PILOT DIAMETER | 0.7494 INCHES MINIMUM AND 0.7497 INCHES MAXIMUM |
AAVM | PILOT LENGTH | 0.0600 INCHES MINIMUM AND 0.0700 INCHES MAXIMUM |
ABPA | UNDERCUT DIAMETER | 0.7494 INCHES MINIMUM AND 0.7497 INCHES MAXIMUM |
ABPC | UNDERCUT WIDTH | 0.0850 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.885 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.1246 INCHES MINIMUM AND 0.1248 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.470 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.550 INCHES NOMINAL |
AECZ | MOUNTING LIP DIAMETER | 0.8850 INCHES MAXIMUM |
AEDA | MOUNTING LIP DEPTH | 0.0600 INCHES MINIMUM AND 0.0700 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND,SLOTTED |
AEDZ | SHAFT BEARING TYPE | BEARING |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 340.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 0.30 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 0.30 INCH-OUNCES |
AEFY | SHAFT END PLAY | 0.005 INCHES |
AEGC | SHAFT RADIAL PLAY | 0.001 INCHES |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | CLAMP RING |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 15.3 KILOHMS 1ST SECTION AND 10.0 KILOHMS 2ND SECTION AND 10.0 KILOHMS 3RD SECTION |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 238.0 1ST SECTION AND 283.0 1ST SECTION AND 283.0 2ND SECTION AND 283.0 3RD SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL |
CQFL | FUNCTION CONFORMITY TOLERANCE PER SECTION | -0.40 TO 0.40 1ST SECTION AND-0.50 TO 0.50 2ND SECTION AND-0.50 TO 0.50 3RD SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 85.0 ALL SECTIONS |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 20.0 1ST SECTION AND-90.0 TO 90.0 2ND SECTION AND-90.0 TO 90.0 3RD SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR ALL SECTIONS |
CRGM | FUNCTION CONFORMITY PER SECTION | ALL SECTIONS STEPPED CONFORMITY |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 1ST SECTION AND 1 2ND SECTION AND 1 3RD SECTION |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -1.0 TO 1.0 DEG ANGULAR ROTATION ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -4.0 TO 4.0 ALL SECTIONS |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION |
CSBX | FUNCTION CHARACTERISTIC PER SECTION | ALL SECTIONS TABLE |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 25.0 ALL SECTIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD AND TERMINALS SILVER |
PRMT | PRECIOUS MATERIAL | GOLD AND SILVER |
TEST | TEST DATA DOCUMENT | 98571-808953 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.