Part Number : 154911 | Manufacturer : Tymshare Inc | ||
NSN : 5950-00-259-5774 (5950002595774) | |||
Item Name : Transformer Power | CAGE Code : 56200 | ||
NIIN : 00-259-5774 (002595774) | |||
FSC Code : 5950 Coils and Transformers | |||
FSG Code : 59 Electrical and Electronic Equipment Components | |||
INC Code : 32496 | |||
NCB Code : 00 | Country : USA |
Thank you for taking an interest in part number 154911, that of which is listed with the description Transformer Power; Manufactured by Tymshare Inc and listed alongside the NSN 5950002595774, part number 154911 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
Part Number : 154911 | Manufacturer : Tymshare Inc | ||
NSN Number : 5950-00-259-5774 (5950002595774) | |||
Item Name : Transformer Power | CAGE Code : 56200 | ||
NIIN : 002595774 | |||
FSC CODE : 5950 Coils and Transformers |
Thank you for taking an interest in part number 154911, that of which is listed with the description Transformer Power; Manufactured by Tymshare Inc and listed alongside the NSN 5950002595774, part number 154911 is available for immediate purchase on our website. As such, to learn more about this offering while receiving a competitive quote for your comparisons, be sure to fill out and submit the RFQ form presented on this page. Within 15 minutes of us receiving and reviewing a completed form, a member of our staff will contact you to present a tailored solution for your comparisons.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-259-5774 Item PartTypeName: TRANSFORMER,POWER | 5950 | 002595774 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
154911 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | UNABLE TO DECODE | UNABLE TO DECODE |
AAJF | UNABLE TO DECODE | UNABLE TO DECODE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP8.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT60.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 8.500 INCHES NOMINAL8.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.500 INCHES MAXIMUM6.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 5.540 INCHES NOMINAL5.540 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED,DOUBLE SHELLPARTIALLY INCLOSED,DOUBLE SHELL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT9 SECONDARY SINGLE COMPONENT |
CBME | UNABLE TO DECODE | UNABLE TO DECODE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 44.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY4.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY25.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 127.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 26 WIRE LEAD |
We hope that you will visit us again the next time you need board-level components, aviation and aerospace parts, and more. Allow us to serve as your strategic purchasing partner.
Request for Quote